What Points Need To Be Noted When Using Gr1 ERTi-1 Titanium Welding Wire?

Apr 10, 2024

1, Gr1 ERTi-1 titanium welding wire construction personnel and welders should wear clean white gauze gloves (cotton thread gloves are strictly prohibited).
2, the treated welding area is strictly prohibited to touch and contact with iron objects.

3,Welding work as far as possible indoors, the ambient wind speed should be ≤ 0.5m / s, to avoid the impact of penetrating wind.

4, welding should be used as much as possible short arc welding, using a small welding heat input, the nozzle and the weldment to maintain the angle of 70 ~ 80 degrees.

5, butt tube positioning welding, the butt gap is generally about 0.5mm.

6, each weld should be welded as far as possible, must be welded weld, the interface should be cleaned up before welding, welding meat lap length of 10 ~ 15mm.

Ti6AL4V Medical Spool WireTi -15333 Ti Alloy WireTi-6AL-7Nb Titanium Alloy Wire

CHEMICAL COMPOSITION OF TITANIUM WELDING WIRE FILLER
CLASSIFICATION (Weight %, Max or Range)
AWS A5.16 UNS No Ti C O N H Fe Al V Pd Mo Ni
ERTi 1 R50100 Rem. 0.03 0.03-0.10 0.012 0.005 0.08          
ERTi 2 R50120 Rem. 0.03 0.08-0.16 0.015 0.008 0.12          
ERTi 3 R50125 Rem. 0.03 0.13-0.20 0.02 0.008 0.16          
ERTi 4 R50130 Rem. 0.03 0.18-0.32 0.025 0.008 0.25          
ERTi 5 R56400 Rem. 0.03 0.12-0.20 0.03 0.015 0.22 5.5-6.7 3.5-4.5      
ERTi 7 R52401 Rem. 0.03 0.08-0.16 0.015 0.008 0.12     0.12-0.25    
ERTi 9 R56320 Rem. 0.03 0.08-0.16 0.02 0.008 0.25          
ERTi 12 R53401 Rem. 0.03 0.08-0.16 0.015 0.008 0.15       0.2-0.4 0.6- 0.9
ERTi 23 R56408 Rem. 0.03 0.03-0.11 0.012 0.005 0.2 5.5-6.5 3.5-4.5